| CH01 | Indoor return-air sensor is open or shorted. | Technician |
| CH02 | Indoor inlet pipe sensor is open or shorted. | Technician |
| CH04 | Condensate water is not draining, or the water tank is full. | You can fix |
| CH05 | Communication error between the indoor and outdoor units. | Technician |
| CH06 | Indoor outlet pipe sensor is open or shorted. | Technician |
| CH07 | Units are set to conflicting modes (for example one cooling while another heats). | You can fix |
| CH09 | Indoor unit memory (EEPROM) error. | Technician |
| CH10 | Indoor unit fan problem. | You can fix |
| CH12 | Indoor middle pipe sensor is open or shorted. | Technician |
| CH21 | DC peak / IPM fault: compressor DC voltage too high. | Technician |
| CH22 | AC input current too high (CT2 error). | Technician |
| CH23 | DC link voltage too low. | Technician |
| CH25 | System voltage is too low or too high. | Technician |
| CH26 | Inverter compressor is stuck or not rotating. | Technician |
| CH27 | Prospective short-circuit (PSC) fault. | Technician |
| CH28 | Inverter compressor DC voltage too high. | Technician |
| CH29 | Inverter compressor current too high. | Technician |
| CH31 | Current-transformer thermistor temperature too low. | Technician |
| CH32 | Compressor discharge pipe temperature too high. | Technician |
| CH38 | Low refrigerant level. | Technician |
| CH40 | Outdoor CT thermistor is open or shorted. | Technician |
| CH41 | Compressor discharge pipe sensor is open or shorted. | Technician |
| CH44 | Outdoor inlet-air sensor is open or shorted. | Technician |
| CH45 | Condenser coil middle sensor is open or shorted. | Technician |
| CH46 | Suction line sensor is open or shorted. | Technician |
| CH48 | Coil outlet (liquid line) sensor is open or shorted. | Technician |
| CH54 | Reverse phase detection error, often after a power cut or electrical work. | Technician |
| CH60 | Outdoor board memory (EEPROM) checksum error. | Technician |
| CH61 | Overheating: the outdoor unit in cooling mode, or the indoor unit in heating mode. | You can fix |
| CH62 | Inverter board heat sink temperature too high. | Technician |
| CH63 | Condenser coil pipe temperature too low. | Technician |
| CH65 | Heat-sink sensor is open or shorted. | Technician |
| CH66 | Communication or piping connection fault between indoor and outdoor units. | Technician |
| CH67 | Outdoor unit fan problem. | You can fix |
| CH90 | Protective code shown during a test run. | Technician |
| CH93 | Communication problem between indoor and outdoor units, often during a test run. | Technician |
| CF | Reminder to clean the indoor filter. | You can fix |
| Cl | Auto-clean indicator: the indoor unit may smell. | You can fix |
| dF | Auto-defrost is active (steam may come from the outdoor unit). Not a fault. | You can fix |
| E101 | Communication error between indoor and outdoor units. | Technician |
| E121 | Indoor room temperature sensor is faulty. | Technician |
| E122 | Indoor heat exchanger temperature sensor is faulty. | Technician |
| E154 | Indoor fan is not rotating (fan motor or capacitor fault, or a voltage surge). | Technician |
| E162 | Indoor memory (EEPROM) error. | Technician |
| E163 | Indoor board memory (EEPROM) data is wrong or erased. | Technician |
| E203 | Communication timeout (1 minute) between outdoor inverter and main boards. | Technician |
| E221 | Outdoor temperature sensor error. | Technician |
| E231 | Outdoor coil temperature sensor error. | Technician |
| E251 | Discharge temperature sensor error. | Technician |
| E416 | Compressor discharge temperature too high. | Technician |
| E458 | Outdoor fan error. | Technician |
| E461 | Compressor start-up error. | Technician |
| E462 | Trip / PFC over-current error. | Technician |
| E464 | IPM over-current error. | Technician |
| E467 | Compressor rotation error. | Technician |
| E468 | Current sensor error. | Technician |
| E469 | DC-link voltage sensor error. | Technician |
| E470 | Outdoor memory (EEPROM) error. | Technician |
| E471 | OTP error. | Technician |
| E472 | AC line zero-cross signal error. | Technician |
| E474 | Heat-sink sensor error. | Technician |
| E485 | Input current sensor error. | Technician |
| E554 | Refrigerant (gas) leak error. | Technician |
| E556 | Indoor/outdoor capacity mismatch error. | Technician |
| C5 | Jumper cap issue, usually after replacing the control board. | Technician |
| E1 | High pressure (dirty coils, blockage or overcharge). | Technician |
| E3 | Low pressure (dirty filters/coils or low refrigerant). | Technician |
| E5 | Over-current protection (high or unstable supply voltage). | Technician |
| E7 | Mode conflict: indoor and outdoor units set to different modes. | You can fix |
| F1 | Indoor ambient temperature sensor fault. | Technician |
| F2 | Indoor evaporator sensor fault. | Technician |
| F3 | Outdoor ambient sensor fault. | Technician |
| F4 | Outdoor tube sensor fault. | Technician |
| F5 | Discharge sensor fault. | Technician |
| H1 | Defrost mode (a status, usually not a fault). | You can fix |
| H5 | Power module (IPM) in protection mode. | Technician |
| L9 | Power protection mode, possibly after a power surge. | Technician |
| U3 | Voltage drop on the DC bus. | Technician |
| E1 | Indoor temperature sensor failure. | Technician |
| E2 | Pipe temperature sensor failure. | Technician |
| E4 | Indoor board memory (EEPROM) failure. | Technician |
| E5 | Indoor anti-frosting protection. | Technician |
| E7 | Communication fault between indoor and outdoor units. | Technician |
| E9 | Indoor unit overload in heating mode. | Technician |
| E14 | Indoor fan motor malfunction. | Technician |
| F1 | IPM (power module) protection. | Technician |
| F2 | Compressor instantaneous over-current protection. | Technician |
| F3 | Communication error between power module and main board. | Technician |
| F4 | Compressor discharge temperature protection. | Technician |
| F6 | Outdoor ambient sensor failure. | Technician |
| F7 | Suction temperature sensor failure. | Technician |
| F8 | DC fan motor malfunction. | Technician |
| F9 | Module reset. | Technician |
| F11 | Loss of synchronism detection (compressor). | Technician |
| F12 | Outdoor board memory (EEPROM) failure. | Technician |
| F13 | Lack of refrigerant. | Technician |
| F14 | 4-way valve reversing failure. | Technician |
| F19 | Power over/under-voltage protection. | Technician |
| F20 | High-pressure protection. | Technician |
| F21 | Outdoor coil temperature sensor failure. | Technician |
| F22 | Outdoor AC over-current protection. | Technician |
| F24 | Abnormal CT current detection protection. | Technician |
| F25 | Abnormal compressor discharge sensor. | Technician |
| F27 | Compressor current sampling circuit fault. | Technician |
| F28 | Compressor position detection circuit fault. | Technician |
| F35 | Compressor driver board failure. | Technician |
| F43 | Model matching abnormality. | Technician |
| FE | Refrigerant leak detection fault (fixed-speed units). | Technician |
| A1 | Indoor unit board (PCB) fault. | Technician |
| A5 | High-pressure control or freeze-up protection. | Technician |
| A6 | Indoor fan motor fault. | Technician |
| C4 | Heat-exchanger temperature sensor fault. | Technician |
| C9 | Suction air temperature sensor fault. | Technician |
| E1 | Circuit board fault. | Technician |
| E5 | Compressor overload (OL) protection started. | Technician |
| E6 | Compressor start-up failure. | Technician |
| E7 | DC fan motor fault. | Technician |
| E8 | Over-current input. | Technician |
| EA | Cooling/heating switching error. | Technician |
| F3 | Discharge pipe temperature too high. | Technician |
| F6 | High-pressure protection during cooling. | Technician |
| H0 | Sensor fault. | Technician |
| H6 | Operation halted: position-detection sensor fault. | Technician |
| H8 | DC current sensor fault. | Technician |
| H9 | Suction air temperature sensor fault. | Technician |
| J3 | Discharge pipe temperature sensor fault. | Technician |
| J6 | Heat-exchanger temperature sensor fault. | Technician |
| L3 | Electrical parts overheating. | Technician |
| L4 | Inverter heat-sink temperature too high. | Technician |
| L5 | Output over-current. | Technician |
| P4 | Inverter heat-sink temperature sensor fault. | Technician |
| U0 | Refrigerant shortage. | Technician |
| U2 | Voltage drop or main-circuit over-voltage. | Technician |
| U4 | Communication failure between the indoor and outdoor units. | Technician |
| UA | Indoor and outdoor units do not match (combination fault). | Technician |
| AE | Water leak detected; safety function activated. | Technician |
| Cd | Not an error: cool-down after drying. | You can fix |
| CE | Motor over-current. | Technician |
| CL | Not an error: child lock is on. | You can fix |
| dcL | Not an error: nozzle cleaning in progress (about 16 minutes). | You can fix |
| dE1 | Door is not closed properly. | You can fix |
| dE2 | Door is closed but not locked. | You can fix |
| dHE | Temporary error in the drying function. | Technician |
| E80 | Communication fault between the display board and main board. | Technician |
| Ed1 | Liquid detergent pump fault. | Technician |
| Ed2 | Open circuit in the detergent pump. | Technician |
| Ed3 | Softener pump fault. | Technician |
| Ed4 | Open circuit in the softener pump. | Technician |
| Ed5 | Control board communication problem. | Technician |
| FE | Water overfilling. | Technician |
| FF | Freeze failure: temperature inside the washer fell below 1 degree C. | You can fix |
| HE | Temporary heater error. | Technician |
| IE | Not enough water entering the drum. | You can fix |
| LE | The drum cannot turn (motor overload or an object stuck). | You can fix |
| nC | Faulty connection between display board and NFC module. | Technician |
| nE | Connection problem between display board and Wi-Fi module. | Technician |
| nF | Wi-Fi module problem. | Technician |
| OE | The washer cannot drain the water. | You can fix |
| OPn | Detergent drawer is not fully inserted or was opened during operation. | You can fix |
| PE | Water-level sensor problem. | Technician |
| PF | Power failure during a cycle. | You can fix |
| PS | Power supply problem; the washer stops. | Technician |
| SE | Sensor error. | Technician |
| Sud | Too much suds detected. | You can fix |
| tCL | Reminder to run a drum-clean cycle. | You can fix |
| tE | Heating error, usually a faulty temperature sensor. | Technician |
| UE | Unbalanced load in the drum. | You can fix |
| vS | Vibration sensor issue. | Technician |
| 3C | Motor error. | Technician |
| 4C | Water is not filling the drum. | You can fix |
| 4C2 | Hot and cold water hoses are connected to the wrong inlets. | You can fix |
| 5C | Water is not draining. | You can fix |
| 7E | SilverCare system error. | Technician |
| 8C | Motion / vibration sensor (MEMS) error. | Technician |
| 9C6 | High-temperature circuit error. | Technician |
| 9C7 | Hardware over-current error. | Technician |
| 9C8 | Software over-current error. | Technician |
| 18:8J | Model option error. | Technician |
| AC | Communication error between internal boards. | Technician |
| bE | Motor speed sensor error. | Technician |
| Cb | Not an error: calibration mode. | You can fix |
| CL | Not an error: child lock is on. | You can fix |
| dC | The door is not detected as closed and locked. | You can fix |
| ddC | The Add Door was opened or not closed fully. | You can fix |
| dn | Not an error: software update downloading. | You can fix |
| E2 | A control-panel button is stuck. | You can fix |
| HC | Heater error. | Technician |
| LC | Water-level / possible leak error. | You can fix |
| OE | Too much water in the drum (overflow). | You can fix |
| PC | Clutch position error. | Technician |
| PC1 | Clutch hall-signal error. | Technician |
| PF | Voltage / power supply error. | Technician |
| SDC | Detergent drawer is not closed properly. | You can fix |
| SF | System error. | Technician |
| Sr | System relay error. | Technician |
| SUd | Too many suds. | You can fix |
| tE | Temperature sensor error. | Technician |
| Ub | Unbalanced load. | You can fix |
| CL | Child lock is on (not an error). | You can fix |
| E:00 | General appliance fault (some -18 variants mean the drain pump is blocked). | Technician |
| E16 | The door is not locked properly. | You can fix |
| E17 | Water is not entering fast enough: the inlet filters are blocked or the water pressure is low. | You can fix |
| E18 | The washer cannot drain: drain filter or drain hose is blocked or kinked. | You can fix |
| E19 | Heating time exceeded (the water does not heat up). | Technician |
| E20 | Unexpected heating. | Technician |
| E23 | Leak: water in the base of the machine or the AquaStop safety has triggered. | Technician |
| E25 | Turbidity (water cleanliness) sensor fault. | Technician |
| E26 | Analogue pressure (water level) sensor fault. | Technician |
| E27 | Pressure sensor fault. | Technician |
| E28 | Flow sensor problem. | Technician |
| E32 | Unbalanced load: the spin was interrupted. | You can fix |
| E33 | Too much foam detected. | You can fix |
| E56 | Communication error. | Technician |
| E80 | Drive circuit fault. | Technician |
| Tap symbol | Water supply problem: low pressure, or a blocked or kinked supply hose. | You can fix |
| CL | Child lock is on (not an error). | You can fix |
| E:00 | General appliance fault. | Technician |
| E16 | The door is not locked properly. | You can fix |
| E17 | Water is not entering fast enough: the inlet filters are blocked or the water pressure is low. | You can fix |
| E18 | The washer cannot drain: drain filter or drain hose is blocked or kinked. | You can fix |
| E19 | Heating time exceeded (the water does not heat up). | Technician |
| E20 | Unexpected heating. | Technician |
| E23 | Leak: water in the base of the machine or the AquaStop safety has triggered. | Technician |
| E25 | Turbidity (water cleanliness) sensor fault. | Technician |
| E26 | Analogue pressure (water level) sensor fault. | Technician |
| E27 | Pressure sensor fault. | Technician |
| E32 | Unbalanced load: the spin was interrupted. | You can fix |
| E33 | Too much foam detected. | You can fix |
| Tap symbol | Water supply problem: low pressure, or a blocked or kinked supply hose. | You can fix |
| dET | Detergent cartridge not detected. | You can fix |
| F5 E2 | The door is not locking properly. | You can fix |
| F7 E1 | Motor speed sensing error. | You can fix |
| F8 E1 | Low water flow into the washer. | You can fix |
| F8 E2 | Dispenser system problem. | You can fix |
| F9 E1 | Draining takes longer than expected (over about 8 minutes). | You can fix |
| Int | The cycle was paused or cancelled. | You can fix |
| LOC | Control lock is on (not an error). | You can fix |
| rL | Items were detected during the Clean Washer cycle. | You can fix |
| Sud | Too many suds. | You can fix |
| F01 | Electronic board (circuit) fault. | Technician |
| F02 | Motor circuit fault: the drum turns intermittently or not at all. | Technician |
| F03 | Temperature sensing fault: no heating. | Technician |
| F05 | Drain blockage or pump problem: water stays in the drum or the door will not open. | You can fix |
| F06 | Door lock fault: the door will not open/close or the programme will not start. | Technician |
| F07 | Electronic board or heating circuit fault: programme pauses, no heating, pump runs continuously. | Technician |
| F08 | Heater fault: programme pauses part-way through the wash. | Technician |
| F09 | Software fault: many flashing lights and no programme can be selected. | Technician |
| F11 | Pump circuit fault: water stays in the machine. | Technician |
| F12 | Electronic control fault: the machine will not turn on. | Technician |
| F13 | Drying temperature sensing fault. | Technician |
| F15 | Heater control fault. | Technician |
| F16 | Drum lock position sensor fault. | Technician |
| F18 | Internal data error: some displays or functions do not work. | Technician |